PLC Shift Device and OS Support

For most PLC Shift solutions, three components are required.  A supported Linux device or OS to execute the PLC Shift run-time, a PLC/RTU for its tag database, site specific logic and connection to IO,  and the physical IO itself. We've compiled a list of tested Linux devices, OS, PLCs (physical and virtual) and IO.  You can filter the list below based on your specific requirements.  

 

These components can be mixed and matched in many different way.  For example, the Linux device can run PLC Shift and communicate to an existing PLC, or the Linux device can also be the PLC with Codesys installed and IO, or a Linux based PLC with IO such as an Groov EPIC can also serve as the Linux device.

Don't see the device you want to use?  Contact us and we'll check it out

PLC Shift Groov RIO

Opto 22 Groov RIO

Protocol:

Codesys OPC-UA

Cost:

Cert:

Temp:

Scale:

Low

UL, CE, CLASS I DIV 2

-20

to

70

°C

Low

PLC Shift CompactLogix

Rockwell CompactLogix PLC

Protocol:

EthernetIP

Cost:

Cert:

Temp:

Scale:

Medium

CE, CLASS I DIV 2, UL

0

to

60

°C

Medium

PLC Shift XetaEdge

Xetawave XetaEdge

Protocol:

Codesys OPC-UA, EthernetIP, ModbusTCP

Cost:

Cert:

Temp:

Scale:

Low

UL, CE, CLASS I DIV 2

-40

to

85

°C

Low

PLC Shift SCADAPack 474i

Schneider Electric SCADAPack 470i/474i RTU

Protocol:

SCADAPack 470i API, ModbusTCP

Cost:

Cert:

Temp:

Scale:

Medium

UL, CE, CLASS I DIV 2

-40

to

70

°C

Medium

PLC Shift Moxa

Moxa 8210, 1222A, 2222A

Protocol:

Codesys OPC-UA, EthernetIP, ModbusTCP

Cost:

Cert:

Temp:

Scale:

Low

UL, CE, CLASS I DIV 2

-40

to

70

°C

Medium

PLC Shift Raspberry Pi

Raspberry PI OS 10 /11

Protocol:

Codesys OPC-UA, EthernetIP, ModbusTCP

Cost:

Cert:

Temp:

Scale:

Very Low

CE

0

to

50

°C

Medium

PLC Shift Groov EPIC

Opto 22 Groov EPIC

Protocol:

Codesys OPC-UA

Cost:

Cert:

Temp:

Scale:

Medium

UL, CE, CLASS I DIV 2

-20

to

70

°C

High

PLC Shift Phoenix Contact PLC Next

Phoenix Contact PLC Next AXC F 2152

Protocol:

Codesys OPC-UA

Cost:

Cert:

Temp:

Scale:

Medium

UL, CE, CLASS I DIV 2

-25

to

60

°C

Medium

PLC Shift FloBoss 107

Emerson FloBoss 107

Protocol:

ModbusTCP

Cost:

Cert:

Temp:

Scale:

Medium

UL, CE, CLASS I DIV 2

-40

to

75

°C

Medium

PLC Shift SCADAPack 32

Schneider Electric SCADAPack 32 / 300 / 470 / 474 RTU

Protocol:

ModbusTCP

Cost:

Cert:

Temp:

Scale:

Medium

UL, CLASS I DIV 2

-40

to

70

°C

Medium

PLC Shift IOT-GATE-iMX8

Compulab IOT Gateway iMX8

Protocol:

Codesys OPC-UA, EthernetIP, ModbusTCP

Cost:

Cert:

Temp:

Scale:

Low

UL, CE

-40

to

80

°C

Medium

PLC Shift Ubuntu Server

Ubuntu Server 20.04 / 22.04 LTS x86_64

Protocol:

Codesys OPC-UA, EthernetIP, ModbusTCP

Cost:

Cert:

Temp:

Scale:

to

°C

High

PLC Shift ControlLogix

Rockwell ControlLogix PLC

Protocol:

EthernetIP

Cost:

Cert:

Temp:

Scale:

High

UL, CE, CLASS I DIV 2

0

to

60

°C

High

PLC Shift CODESYS

CODESYS Runtime Soft PLC - ARM / x86

Protocol:

Codesys OPC-UA

Cost:

Cert:

Temp:

Scale:

Low

to

°C

High

PLC Shift FloBoss 1100

Emerson FloBoss 1100/1200

Protocol:

ModbusTCP

Cost:

Cert:

Temp:

Scale:

Medium

UL, CE, CLASS I DIV 1

-40

to

80

°C

Low

PLC Shift  RevPi

Kunbus RevPi PLC

Protocol:

Codesys OPC-UA

Cost:

Cert:

Temp:

Scale:

Low

CE, UL

-25

to

55

°C

High

PLC Shift OlinuXino

Olimex OlinuXino STMP157

Protocol:

Codesys OPC-UA, EthernetIP, ModbusTCP

Cost:

Cert:

Temp:

Scale:

Very Low

-45

to

85

°C

Medium