PLC SHIFT

WELL TEST
Oil and gas well testing solution with AGA/API compliant measurement and simplified reporting
WELL TEST cost effectively measures gas, oil and water production from several wells in close proximity to each other. Manual or automated valves are used to direct the flow from a single well through a test separator. This separator employs measurement devices and flow computers to determine flow accumulation for each component (gas, oil and water) over a set period of time.
Key Features
Seamless Integration With PLC SHIFT Flow apps
Connects internally to PLC SHIFT Gas Flow and Liquid Flow apps for configuration, control, and status of the apps.
Well Configurations
Store up to 20 individual well configurations including
Gas Composition
Liquid density - For API Corrections
Liquid Product Type - ie Crude Oil, NGL - For API Corrections
Base Density of Oil and Water - Inferred Water Cut
Correction Factor Oil
Correction Factor Water
Well Test Control
Select Well on Test
Start/Stop Test
End Purge Manually
Advanced Data Handling
Each well has a configurable "Asset ID" This is a unique identifier that is included in all data records generated by all connected Flow Computer apps.
Each well test has a unique "Batch ID". The same batchID is and included in all data records generated by all connected Flow Computer apps.
These two identifiers make reporting trivial in SCADA and SQL database systems as it provides a reliable key to join and filter data across dozens of data tables.
We have built a sample report with interactivity using Microsoft Power BI desktop reporting tools. Desktop format can be found online at this link. A simpler version that is suitable for mobile devices is here.
Compliant with API MPMS 21.1 and 21.2 and AER Directive 17
Double precision float accuracy
Daily, Hourly and minute history logs
Configuration change logs
EFM Event log
EFM Alarm log
QTR (Quantity Transaction Record)
Direct polling of multivariable via Modbus
Modern and Secure Access Control via SSH
Flow Computer Accuracy Testing and Validation
Algorithms and accumulations are validated against industry standard test cases
Read more about flow computer accuracy in the Reference Manual
Protocol and Application Support
Allen Bradley Ethernet/IP
Tag data and UDT via connected PLC
ModbusTCP
Tag data via connected PLC
Modbus Master
Poll data from multivariable transmitters using ModbusTCP, Modbus RTU in TCP, or Modbus RTU
MS SQL and Azure Table Storage
Export tabular data directly from the app to database
Daily, Hourly and Minute History
QTR History
EFM Alarm, Event and Configuration change log
App diagnostic logs
MQTT SparkplugB
Report by Exception tag data with history and tabular data
Azure Event Hub
Stream tag data to Azure for real-time anaytics
SSH
Secure Shell for User Access Control
Ignition SCADA
Requires Cirrus Link MQTT Software including Cirrus Link MQTT Recorder Module
SCADA system - MQTT Software for IIoT - Cirrus Link Solutions (cirrus-link.com)