top of page
background.jpg

PLC SHIFT

LIQUID FLOW

LIQUID FLOW

API Compliant Liquid and Net Oil Flow Computer. API 11.1, 11.2, 11.4.1. Includes hourly and daily history, event and alarms log and QTR.

LIQUID FLOW is a full featured, API compliant liquid hydrocarbon flow computer app for PLC SHIFT. Accurate and reliable measurement is critical for custody transfer and precise process control.  Reliable measurement requires auditability to ensure accuracy.  


Key Features


API 11.1, 11.2.1, 11.2.2

Temperature and Pressure Volume Correction for Generalized Crude Oils, Refined Products, Lubricating Oils, NGL and LPG


API 11.4.1, API 20.4

Temperature Volume Correction for Water and Produced Water


Net Oil

Net Oil and Net Water calculation with support for water cut analyzer or inferred method with Coriolis meter.


Coriolis Meter Support

Directly poll the following meters;

  • Micromotion 2700, 5700

  • E+H Promoss 83, 100, 300 and 500

  • Krohne MFC 400


Compliant with API MPMS 21.1 and 21.2 and AER Directive 17

  • Double precision float accuracy for internal calculation and record export

  • Daily, Hourly and minute history logs

  • Configuration change logs

  • EFM Event log

  • EFM Alarm log

  • QTR (Quantity Transaction Record)

  • Modern and Secure Access Control via SSH


Flow Computer Accuracy Testing and Validation

  • Algorithms and accumulations are validated against industry standard test cases

  • Read more about flow computer accuracy in the Reference Manual

Well Testing

Combine with PLC Shift Gas Flow to solve complex measurement requirements such as Well Testing. Read more about the PLC SHIFT Well Testing solution.


Protocol and Application Support


Allen Bradley Ethernet/IP

Tag data and UDT via connected PLC


ModbusTCP

Tag data via connected PLC


Modbus Master

Poll data from Coriolis meter using ModbusTCP, Modbus RTU in TCP, or Modbus RTU


MQTT SparkplugB

Report by Exception tag data with history and tabular data


Azure Event Hub

Stream tag data to Azure for real-time anaytics


Azure Table Storage

Export tabular data from the app to Azure

  • Daily, Hourly and Minute History

  • QTR History

  • EFM Alarm, Event and Configuration change log

  • App diagnostic logs


SSH

Secure Shell for User Access Control


Ignition SCADA

Requires Cirrus Link MQTT Software including Cirrus Link MQTT Recorder Module

SCADA system - MQTT Software for IIoT - Cirrus Link Solutions (cirrus-link.com)



PLC SHIFT Features


PLC SHIFT MANAGER

Configuration, management and operations tool


Azure Event Hub Export

Stream tag data to Azure Event Hub and enable real-time analytics


MQTT SparkplugB Export

Export tag and historical data via MQTT SparkplugB to SCADA, Historians and more.


Secure Connections

Modern security and encrytion methods such as SSH and TLS for user access and data connectivity


App Tiers


Liquid Flow is available in free and paid tiers.





bottom of page